Maintenance and Calibration of Automated Thermal Cycler
✅ Maintenance
✅ Temperature Verification / Thermal Calibration
Applied Biosystems Automated Maintenance and Calibration Services:
- Extensive hands-on experience with older Applied Biosystems Automated models
- Fast response and free consultation
- In-depth inspection beyond basic cleaning
- Calibration using specialized, high-precision measuring instruments
- Clear and detailed calibration reports
The Automated Thermal Cycler from Applied Biosystems, a Thermo Fisher Scientific brand, is one of the most advanced automated PCR solutions available. Designed specifically for laboratories requiring high-throughput sample processing with maximum reliability, this automated PCR system delivers large volumes of results with minimal manpower and time.

The instrument stands out with its space-saving modular design, an automatic sliding heated lid, precise plate-handling mechanism, and seamless integration with robotic systems from leading manufacturers such as Beckman Coulter, Hamilton Robotics, Tecan, and Thermo Fisher. This integration makes the PCR workflow fully automated, significantly reducing manual errors and cross-contamination while ensuring highly accurate and reproducible DNA amplification results.
However, despite its superior performance, regular maintenance and calibration are critical factors in maintaining long-term temperature accuracy. In laboratory environments across both developed and developing countries, where PCR run frequency is increasingly high, neglecting maintenance can lead to serious result deviations.
Why Automated Thermal Cycler Maintenance Is Necessary
The Automated Thermal Cycler performs thousands of thermal cycles continuously, making it highly susceptible to the accumulation of dust, chemical residues, mechanical wear, and environmental temperature fluctuations.
Without scheduled maintenance, issues such as contamination of the thermal block, reduced cooling fan efficiency, inconsistent performance of the automatic lid, or misalignment of the plate ejectors can occur.

These problems directly compromise temperature uniformity across wells, leading to inconsistent PCR results, wasted precious samples, and expensive high-grade reagents.
Regular maintenance enables early detection of performance degradation before it affects the entire automated workflow. Maintaining the precision of the automatic lid mechanism and plate-handling system is especially crucial, as any deviation can disrupt the robotic cycle.
Experts recommend performing maintenance at least 1 to 2 times per year or after approximately 500 thermal cycles, depending on the laboratory’s workload. This not only extends the instrument’s lifespan but also ensures it continues to operate at optimal performance, particularly when integrated into high-throughput automation systems.
The Importance of Calibrating the Automated Thermal Cycler
Calibration is a critical step in ensuring the Automated Thermal Cycler maintains absolute temperature accuracy, the core requirement of every PCR reaction. DNA amplification demands precise control of three key temperatures: Denaturation at 95°C, Annealing at 50 đến 65°C, and Extension at 72°C. Even a small deviation of 0.5–1°C can cause amplification failure, especially in sensitive assays such as qPCR, multiplex PCR, or low-input samples.
You can refer to: Laboratory equipment repair services
Thermo Fisher Scientific has responded to user needs by offering the Multiplex Dynamic Temperature Verification Service — an on-site dynamic temperature calibration service performed by certified professional engineers.

This service uses traceable measurement systems that comply with international standards to verify temperature accuracy, well-to-well uniformity, overshoot/undershoot, and ramp rates. Detailed results are documented in a comprehensive report, allowing laboratories to confirm that the instrument meets the manufacturer’s technical specifications.
Regular calibration is strongly recommended at least once per year or after any major repair. It is a mandatory requirement for compliance with quality standards such as ISO 17025, GMP, or regulations for medical diagnostic laboratories. Failure to calibrate on time may result in false negative or false positive results, or unreliable data, which can seriously impact scientific research and clinical diagnostics.
Maintenance and Temperature Calibration Procedure for Automated Thermal Cycler
The maintenance and temperature calibration process for the Automated Thermal Cycler is carried out systematically through multiple specialized steps to ensure the highest possible performance.
1. Basic Maintenance and Thorough Cleaning
Service engineers begin with comprehensive cleaning of all external surfaces, the thermal block, heated lid, cooling fans, and mechanical components. For the Automated Thermal Cycler (ATC), special attention is given to inspecting and lubricating the automatic sliding lid mechanism and plate ejectors to ensure consistent plate positioning when the robot loads samples. Removing dust and chemical residues prevents contamination and maintains stable heating and cooling rates.
2. In-Depth Temperature Verification and Calibration
Using a dedicated Temperature Verification Kit, engineers measure temperature at multiple well positions to assess accuracy and uniformity. The process typically includes running tests at standard temperatures such as 95°C, 60°C, and 4°C, while recording ramp rates, overshoot, undershoot, and hold times. If deviations are detected, calibration adjustments and thermal block remapping are performed.

For the Automated Thermal Cycler, calibration also includes verification of software compatibility, firmware, and SiLA Rapid Integration protocols to ensure seamless robotic operation. Upon completion, a full test cycle is run to confirm that the entire system functions normally. The entire process usually takes several hours to one full working day. The laboratory receives a detailed calibration report for quality documentation.
Thermo Fisher strongly recommends using their on-site temperature verification service for the fastest and most accurate results. In addition, preventive maintenance includes inspection and replacement of wear-prone components (such as seals and O-rings) when necessary, helping to prevent unexpected downtime in automated workflows.
The Value of Maintaining and Calibrating the Automated Thermal Cycler
Investing in regular maintenance and calibration of the Automated Thermal Cycler delivers exceptional value to any laboratory:
- Ensures absolutely accurate, reproducible, and reliable PCR results. Tight temperature control optimizes DNA amplification efficiency, minimizes errors, and significantly reduces the time and cost associated with repeat experiments.
- Maintains high productivity in automated environments. Since the Automated Thermal Cycler is designed for high-throughput workflows, stable performance ensures continuous robotic operation without interruptions caused by temperature or mechanical issues.
- Supports compliance with strict regulations. Professional calibration reports serve as important evidence for audits, ISO accreditation, GMP compliance, or medical diagnostic standards in Vietnam, helping laboratories avoid legal risks.
- Delivers long-term cost savings. Scheduled maintenance helps detect and resolve issues early, preventing expensive major repairs or full instrument replacement. Thermo Fisher offers comprehensive service packages that include temperature verification, extended warranty, and rapid technical support.
In summary, maintenance and calibration of the Automated Thermal Cycler is not merely a routine technical task, it is a strategic measure to enhance data quality, optimize operational efficiency, and ensure the long-term reliability of the Automated Thermal Cycler system.
If your laboratory is using an Automated Thermal Cycler, we recommend planning your maintenance and calibration schedule today to avoid unnecessary risks.
You may also be interested in: Laboratory Equipment Calibration
Be the first to review “Maintenance and Calibration of Automated Thermal Cycler” Cancel reply
Related products
Applied Biosystems
Applied Biosystems
Maintenance and Calibration of the ABI 7300 Real Time PCR System
Applied Biosystems
Applied Biosystems
Applied Biosystems
Applied Biosystems
Maintenance and Calibration for the 7500 Real Time PCR System
Applied Biosystems
Applied Biosystems

Tiếng Việt


Reviews
There are no reviews yet.